2.6 Sensor connection
When the sensor is separate from the electronics the sensor cable is connected at the rear of
the instrument. The connections are the following:
Terminal
1
Top coil (red)
2
Bottom Coil (black)
3
Ground (main shield)
17
Rear Electrode (white)
18
Jumper to terminal 19
19
Electrodes shield
20
Front electrode (black)
3 BASIC FUNCTIONS DESCRIPTION
The Flomid-MX has four push buttons for the setting up and operation of the instrument.
NOTE:
When two push buttons should be pushed together, it is recommended to push first one, then
the second and then release both at the same time.
3.1 Control Panel
1.
Push button
- To enter into the batch quantity set-up mode.
- Together with the
push button, to enter the set-up
- Together with the
push button, to reset the total volume counter
Set-up mode
- To move to the next digit.
2.
Push button
- To start a batching process.
Set-up mode
- To confirm the data entered.