Tecfluid TH5 For DP Series Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Sensores Tecfluid TH5 For DP Series. Tecfluid TH5 For DP Series User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 12
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
SC / SCH / SCV / SM / DP / LP
Transmitters HALLTEC V
TH5, TH5T, TH5H, TH5TH
For Series
R-MI-TH5 Rev.: 1 English version
instrumentation
for fluids
Instructions Manual
Vista de página 0
1 2 3 4 5 6 ... 11 12

Resumo do Conteúdo

Página 1 - Instructions Manual

SC / SCH / SCV / SM / DP / LP Transmitters HALLTEC V TH5, TH5T, TH5H, TH5TH For Series R-MI-TH5 Rev.: 1 English version instrumentation for fluids

Página 2

The marking of the equipment shows the following characteristics: - Manufacturer - Model - Serial number (year of construction and number) - CE marki

Página 3 - Flow rate

Problem Probable cause Remedy The analog output gives always 0 mA Cables disconnected. Check the cable connection. The pointer rubs on the scale

Página 4 - 12 to 36 VDC

WARRANTY Tecfluid S.A. GUARANTEES ALL ITS PRODUCTS FOR A PERIOD OF 24 MONTHS, after consignment, against all defects in materials and workmanship. Thi

Página 5

2 TABLE OF CONTENTS 1 INTRODUCTION ... 3 2 MODELS ...

Página 6

3 1 INTRODUCTION The Halltec V transmitter is an electronic position transducer with a microprocessor. The instrument uses the Hall effect to capture

Página 7

The connection is made in the terminal block. The positive terminal of the power supply is connected to the position + and the positive terminal of th

Página 8

5 Note: The reset terminals are not isolated from the rest of the circuit. They may not be connected to other equipment. Example of the connection of

Página 9

In order to establish HART TM communication, it is necessary to connect a terminal or PC with a HART TM modem, in one of the points indicated in the f

Página 10

Resume of the principal communication characteristics: Manufacturer, Model and Revision Tecfluid S.A., TH5H, Rev. 0 Device type Transmitter HART r

Página 11

9 LP SERIES Since LP series are level measuring instruments, they will be available only with TH5 and TH5H models. For HART TM communication, the meas

Página 12

Maximum frequency: 2 Hz. Pulse duration: Aprox. 250 ms. Totalizer: 8 digits. (7 + one decimal. Reset by means of potential free contact). 10.3