5.2 Of the metering body
The following faults may be appear:
 Magnetic coupling deterioration,
 Deterioration of the torsion or reading spring,
 Wearing out of torsion shaft bearings,
 Wearing out or deterioration of the lever and target disk.
If any of these breakdowns occurs, it is preferable to repair it in TECFLUID S.A.
workshops, as a new calibration will be normally necessary.
6 CLEANING
In line
Pass the normal cleaning agent through the installation.
In the workshop
It should be done with soft brushes. Never use sharp objects or metal brushes.
7 TECHNICAL CHARACTERISTICS
Accuracy: DP65: ± 2.5% full scale
DP500: ± 4% full scale
Rangeability: 10:1
Scale length: ~100 mm.
Scales: Direct according to fluid to be measured or in %.
Operation: Vertical with upwards flow (BD)
Vertical with downwards flow (DAB)
Horizontal with right to left flow (DES)
Horizontal with left to right flow (ED)
Connections: DP65 Between flanges.
DP500 EN 1092-1, ANSI, JIS flanges.
Other flange standards on request.
Materials: Body: Plastic coated steel, EN 1.4404 (AISI 316L)
Indicator housing: IP65 in coated aluminium (standard)
EN 1.4404, PP, others on demand
Working pressure:
PN40 DN40 DN80
PN16 DN100 DN300
PN10 DN250 … DN500 (DP500)
Other pressure ratings available on request.
Process temperature:
- Body in plastic coated steel: -20ºC … +130ºC.
- Body in EN 1.4404 (AISI 316L), PTFE bearings: -20ºC … +150ºC.
- Body in EN 1.4404 (AISI 316L): bronze bearings: -20ºC … +300ºC.