Level switch LD61N Instructions Manual R-MI-LD61N Rev.: 0 English Version instrumentation for fluids
2 1. WORKING PRINCIPLE The LD61N level switch is based on the variation of the natural resonant frequency of a vibrating fork, when it comes into cont
Once the connector is opened, pass the cables through the cable gland and screw in the cables in their positions, depending on the desired working mod
When the LD61N is connected for maximum level detection, the current of the NAMUR circuit is “high” (> 2.1 mA) when the sensor is not in contact wi
7. TECHNICAL CHARACTERISTICS Materials: Fork: EN 1.4404 (AISI 316L). Others on demand. Housing: Polycarbonate. Process connection: Threads G1 (BS
6 Dimensions: TF DIN405 Rd52x1/6 Clamp (ISO 2852) Power supply: Minimum voltage: 8 VDC Maximum voltage: 14 VDC Consumption: From 0.7 mA to
7 G1 or 1” NPT thread LD61N ML 7.1 Safety characteristics Given that this instrument is group II, it is intended for use in places likely to be
8. MARKING The marking of the equipment shows the following characteristics: - Manufacturer - Model - Serial number (year of construction and number)